Page 202 - Water Standards
P. 202

Table 4   1   2-2 (Continue)


                                                                       Lateral water stop
                                                                                           Lateral wheels
          No         Embedded parts       Bottom sill  Door head          seat plate
                                                                                            guide plate
                                                                   Submersible  Top exposed
                                 B<100       1           1            1            1           2
                         Surface
                        width within  B =
                                            1   5        1   5       1   5        1   5       2   5
               Working  the working 100-200
                surface   range
          9
               distortion        B>200       2                        2            2           3
                  f
                           Allowable increase
                        in value outside of the                       2            2           2
                        working range



           Notes: 1   L is the width of sluice gate  
                2   Generally, the door head is fixed last during the installation, so the position of the door head should be adjusted according to the
                  actual position of the gate leaf  
                3   Working range means the orifice height  
                4   Measure at least one point per meter for each member/ part  
                5   If the submersible lateral water stop seat plate is made of stainless steel, the misalignment of the whole unit shall be 0   5mm  
                6   The location of the misalignment of the whole group shall be smoothed into a gentle slope  
   197   198   199   200   201   202   203   204   205   206   207