Page 200 - Water Standards
P. 200

Table 4   1   2-2  Allowable error of embedded parts in tainter gate installation  Unit: mm

                                                                       Lateral water stop
                                                                                           Lateral wheels
                     Embedded parts       Bottom sill  Door head          seat plate
                                                                                            guide plate
                                                                   Submersible  Top exposed
          No  

                       Diagram


                                                         +2
          1     Distance                    ±5
                                                         -1
          2     Elevation                   ±5
                Distance from door head center to
          3                                              ±3
              bottom sill surface h
               Distance                                                           +3           +3
                        In the working range  ±5                      ±2
               from hole                                                          -2           -2
          4
               centerline                                             -4          +6           +6
                        Out of working range
                  b                                                   -2          -2           -2
               Elevation
              difference of  L≥10000         3
                working
          5
                surface
              between the   L<10000          2
               two ends
   195   196   197   198   199   200   201   202   203   204   205